WAM™ 800
Essilor
Aberrometer
The Essilor WAM™ 800 is a multifunction diagnostic platform designed to provide comprehensive eye physiology screening within a fast, automated examination.
Using wavefront technology together with objective refraction, corneal topography, keratometry, pachymetry, tonometry and pupillometry, the WAM 800 brings multiple measurements together within a single system. The device is designed to complete a comprehensive screening in less than two minutes.
Its diagnostic capabilities support the assessment of several areas of ocular health. Retroillumination provides detailed visualization of crystalline-lens opacity for cataract screening, Placido-ring topography supports corneal and keratoconus assessment, and tonometry combined with pachymetry and anterior-chamber measurements provides additional information for glaucoma screening and monitoring.
The WAM 800 also extends beyond ocular-health screening into visual-performance assessment, allowing practitioners to evaluate day and night vision, pupillary behaviour and near-vision eye fatigue.
Key Features
Fully automatic multifunction screening
Wavefront aberrometry
Objective refraction and keratometry
Corneal topography
Pachymetry
Tonometry
Pupillometry
Retroillumination
Anterior-chamber analysis
Cataract screening support
Keratoconus screening support
Glaucoma screening and monitoring support
Day/night vision simulation
Near-vision and eye-fatigue assessment
Predefined examination protocols
Guided touchscreen interface
Integrated printer
Technical Specifications
Wavefront Method: Shack-Hartmann
Sphere Range: -20.00 D to +20.00 D
Cylinder Range: 0 D to +8 D
Axis: 0°–180°
Minimum Measurable Pupil: 2 mm
Wavefront Measuring Points: Up to 1,500
Acquisition Time: 0.2 sec
Tonometry Range: 1–50 mmHg
Pachymetry Range: 150–1,300 µm
Iridocorneal Angle Range: 0°–60°
Topography Rings: 24
Topography Measuring Points: 6,144
Analyzed Corneal Points: More than 100,000
Topography Method: Placido rings
Display: 10.1-inch multitouch
Integrated Printer: Yes
Connectivity: RS232 / USB / VGA / LAN
Dimensions: 320 × 555 mm
Weight: 60 lb
Power Supply: 100–240 V AC, 50/60 Hz
Screening & Assessment Capabilities
Cataract Screening
Infrared retroillumination provides a detailed view of crystalline-lens opacity to assist with cataract screening.
Keratoconus Assessment
Placido-ring topography analyzes more than 100,000 corneal points and provides a keratoconus probability index.
Glaucoma Screening & Monitoring
Tonometry, pachymetry and anterior-chamber measurements help provide additional information for glaucoma assessment.
Visual Performance
Wavefront analysis supports day/night vision simulation and assessment of pupillary behaviour and near-vision eye fatigue.